HTTPS ingest
Each sensor has its own token. The gateway, or a test client, posts a reading to the ingest API. This is the path a pilot can use before MQTT is exposed.
Home / Platform
How it works
IIoT stands for the Industrial Internet of Things. It is sensors, gateways and software on a plant, not a gadget in a kitchen. The reading is useful when the shift can act on it, and when the work order lives in FactoraERP.
Machines, rooms, tanks and meters already know their temperature, their vibration and their load. Industrial IoT collects those signals, keeps them with the factory that owns them, and turns a breach of a limit into an alert and a job. People on the shift see the same picture. Demo readings stay labelled until a real gateway is commissioned.
Temperature, humidity, vibration, current, energy, level, flow, weight and door contacts on the machine or the room. A 4–20 mA signal comes in through a Modbus input module, because the gateway’s onboard analog input is not always a current loop.
A certified serial gateway polls Modbus RTU and RS485 and publishes the engineering units. A site router sits at the switchboard for Ethernet PLCs, meters and the site uplink. One gateway covers a process area, not the whole factory. Hardware is multi-vendor: LoRaWAN, Modbus and 4G/LTE.
Dual SIM LTE where fibre is unreliable, Ethernet where the plant LAN is already there. The gateway calls out over HTTPS or MQTT. The factory firewall does not have to accept an inbound connection.
Industrial IoT checks the per-sensor token, stores the reading against that factory only, and shows it to the people signed into the plant. A reading from the simulator stays labelled demo data.
Alerts, OEE, energy per unit and condition trends for the shift. The point is a number the next shift can act on, not a chart that needs an analyst to explain it.
Downtime, counts, energy and quality are shaped to become work orders, batch records and cost in FactoraERP. Batches, products, shifts and targets come back the other way. That exchange is commissioned with the implementation.
The six layers carry the sample. These six steps are what the shift does with it.
A monitored point reports onto the floor: temperature, door, energy, vibration, machine state, and the rest of the catalog.
Alerts go out on WhatsApp, SMS and email once the plant’s messaging accounts are connected, and they escalate if the person on shift does not take them.
An alarm is built to open a maintenance work order for the shift, instead of waiting for someone to retype it. The FactoraERP exchange is commissioned with the implementation.
The person on shift taps the card. The alert stores their name, not a role code, and they can resolve it from the same card.
Stage conditions stay with the batch that was in the room. The plant can produce a PDF of that record.
Spoilage, energy and downtime are shaped to land on the batch in finance, in the same record as the lot.
| Time (EAT) | Point | °C | Band | Result | Acknowledged | Batch |
|---|---|---|---|---|---|---|
| 00:48 | Cold room B · probe 1 | 3.9 | 0–4 | In band | — | LOT-1842 |
| 01:12 | Cold room B · probe 1 | 5.4 | 0–4 | Excursion | Night-shift technician (sample) · 01:18 | LOT-1842 |
| 01:46 | Cold room B · probe 1 | 3.7 | 0–4 | Back in band | — | LOT-1842 |
Each sensor has its own token. The gateway, or a test client, posts a reading to the ingest API. This is the path a pilot can use before MQTT is exposed.
The intended path for an industrial gateway that publishes readings. MQTT from the factory, with a per-gateway identity, stays on the roadmap until an authenticated TLS ingress is reviewed. Until then the broker is not published to the factory network.
OPC-UA is mapped node by node, for example ns=2;s=Line1.Crusher.Temperature. The connector exists. A controller brand is not named until a unit of that brand has been read.
The industrial gateway polls the meter or PLC on Modbus RTU, RS485 or Modbus TCP and publishes engineering units. Industrial IoT does not open a port into the factory.
When the connection to the cloud drops, the gateway keeps readings and syncs them later. The screen shows a buffered count, and an operator can choose Sync now or Pause sync. That is store-and-forward for a dropped link. It is not a claim that a battery rides through a power cut.
A power cut that kills the gateway is a different test. This page does not publish how many hours of buffer, which radio is in the box, or a battery. The clock the plant should ask for is East Africa Time, and a gap should stay visible if a sync fails. On-premise hosting is not confirmed.
The gateway and sensor vendor is not decided. This describes roles, not a brand. Hardware is quoted with the pilot after the survey, and there is no price list and no model number.
A certified 4G/LTE gateway with Ethernet, RS232, RS485 and configurable I/O. It polls Modbus RTU devices and forwards readings over HTTPS or MQTT. Dual SIM covers operator failover. Use one at each process area that has serial meters or transmitters. Analog 4–20 mA signals come in through a Modbus RTU input module when the gateway input is a voltage input. The vendor is chosen at the survey.
A multi-vendor router with Ethernet and dual SIM. Use it at the main switchboard or control room where PLCs, drives or meters speak Modbus TCP, or where the factory LAN needs a managed uplink. LoRaWAN sensors can join the same platform later by publishing MQTT. They are not the path a pilot leads with.
| Category | Examples |
|---|---|
| Climate | Temperature, relative humidity, CO₂ |
| Process | Process temperature, pressure, flow, level |
| Machine | Vibration, current, run contact, running hours |
| Energy and utilities | kW and kWh meters, steam pressure, water volume |
| Quality and mass | Moisture, weight, count |
| Safety contacts | Door, leak. Not a worker-tracking product. |
Industrial IoT is one workspace per plant. People sign in with a factory code. FactoraERP is the system of record the insight is built to update.
The live picture of areas, sensors and what needs attention.
Demand, consumption and intensity against the tariff you enter.
Work orders raised from alerts and from run-hour counters.
Open, acknowledge and escalate. A message sends once a messaging account is connected.
| A connected home | Industrial IoT | |
|---|---|---|
| Job | Comfort in a home | Uptime, energy and quality in a plant |
| Hardware | A gadget on a shelf | A certified sensor, a meter and an industrial gateway on the line |
| Network | Home Wi-Fi | LTE with dual SIM, or the plant LAN, calling out |
| If it fails | An inconvenience | A lost shift, a spoiled batch, or a silent meter |
Industrial Internet of Things. On this site it means Industrial IoT for a plant, a store, a pump house or a mill.
An industrial gateway for Modbus RTU and RS485. A site router where the PLC or meter is on Ethernet, or where the site needs an LTE uplink. The vendor is not decided. Hardware is multi-vendor: LoRaWAN, Modbus and 4G/LTE. No make or model is published.
No. Hardware and the implementation are quoted for the site after the survey. This website has no price list.
When the cloud link drops, the gateway keeps readings and syncs them later. You can see the buffered count, and you can Sync now or Pause sync. That is not a promise that a power cut, a full buffer, or a dead battery leaves no hole. The gateway make, model and battery are unpublished.
Field work opens in FarmMate. A processing plant — tea, dairy, grain — uses a factory dashboard here.