Integrations

The broker, the node, and the brand we will not print.

Connectors are MQTT, OPC-UA, Modbus, PLC and Gateway, plus HTTPS ingest with a token. A controller brand is a different sentence, and this page does not name one.

On the wall

MQTT

The gateway publishes readings. MQTT subscribes to a broker. Authenticated MQTT over TLS from the factory network is the intended path and is labelled as roadmap until that ingress is reviewed.

OPC-UA

Mapped node by node. A node id looks like ns=2;s=Line1.Crusher.Temperature. Bring the address space, not a brochure.

Modbus

Modbus RTU and RS485 on the serial gateway. Modbus TCP on Ethernet, behind the site router. Engineering units are published by the gateway. Industrial IoT does not open a port into the factory.

PLC and gateway

The connector list includes PLC and Gateway. No controller brand is named until a unit of that brand has been read. Bring the nameplate.

HTTPS ingest

Each sensor has its own token, stored hashed. The gateway posts a reading to the ingest API. A pilot can start here.

The floor can show temperature, humidity, door open or closed, process temperature, tank level, weight, a water meter, energy in kilowatts, vibration in millimetres per second, and machine state: running, idle, stopped, fault, maintenance or offline.

Inside FactoraERP

IoT Sensors is Module 11. The factory’s account is issued after onboarding, not from this website. The ERP setting is FactoraERP, another ERP through an integration pack, or none. A plant does not have to replace its system to use the sensors. You do not have to buy a historian and then pay someone to pour it into a second database.

ModuleWhat it already covers
ProductionRecipes, runs and yields
InventoryMaterials, packaging, finished goods
ProcurementSuppliers, requests, spend
QualityLab tests and checkpoints
WarehouseLocations and movements
Supply chainFarm gate to dispatch
HR and payrollPeople, attendance, labour
FinanceCosting, invoices, payments
AnalyticsThe KPIs management already asks for

Those modules are products of the same company, published on factoraerp.com. A parent-ERP screen is not, by itself, a probe. Batch records, the work order an alarm is built to open, and cost on the lot are commissioned with the implementation.

Against a monitoring tool

A category, not a named competitor.

QuestionA monitoring toolIndustrial IoT
Where does the reading live?In the monitoring vendor’s databaseIn the plant workspace, Module 11, on the factory’s own account
Who acknowledged the alert?Often a timestamp, sometimes nobodyA name, stored on the alert
Does the alarm open a work order?Usually a later integration projectAn alarm is built to open a maintenance work order. The exchange is commissioned with the pilot.
Is the excursion on the batch?Export it and retype itTemperature records are shaped to stay on the batch, with a PDF the plant can produce

What the catalog can hold

  • Temperature

  • Humidity

  • Door

  • Process temperature

  • Tank level

  • Weight

  • Water

  • Energy (kW)

  • Vibration (mm/s)

  • Machine state

  • Dew point

  • CO₂

  • Pressure

  • Flow

  • pH

  • Conductivity

  • Moisture

  • Brix

What to photograph

  • The panel door open: whether it speaks Modbus, something else, or nothing you can see. Do not send us a brand to print. Send it so we can say if that unit has been read.
  • Any meter already in the room — energy, flow, temperature — and whether anyone trusts it.
  • The network port, or the place a SIM would have to live, including who pays for data.
  • Whether the reading must stay on site. The host, the region, and whether an on-premise option exists are not confirmed.

If a controller has not been read, the honest end of the conversation is “not yet”. Bring the nameplate. That is the integration.